Radiation Activity converter

How many nuclei decay per second: becquerels, curies and the picocurie figures used in radon reports.

13 units, referenced to the becquerel

Converter

-
Decimals, fractions such as 3/4, and scientific notation such as 1.2e3 all work.

Quick pairs

tap to load

One curie in every radiation activity unit

12 rows
UnitSymbol1 Ci equals
BecquerelBq3.7e10
KilobecquerelkBq37,000,000
MegabecquerelMBq37,000
GigabecquerelGBq37
TerabecquerelTBq0.037
MillicuriemCi1,000
MicrocurieµCi1,000,000
NanocurienCi1,000,000,000
PicocuriepCi1e12
RutherfordRd37,000
Disintegration per seconddps3.7e10
Disintegration per minutedpm2.22e12

How the curie to becquerel conversion works

The becquerel is the SI unit of radioactive activity — one decay per second — and "disintegration per second" in this table is simply that definition spelled out, while "disintegration per minute" is the same count on a slower clock, sixty times smaller numerically for the same activity. The curie is the older, much larger unit, and the jump between the two is enormous: one curie equals 3.7×10¹⁰ becquerel. The sheer size of the curie compared with the becquerel is a direct consequence of how much radioactive material the historical reference sample actually contained, which is why curie-scale quantities translate into becquerel figures with so many zeros attached.

The curie-to-becquerel rule is Bq = Ci × 3.7e10, and the reverse direction multiplies by roughly 2.702703e-11.

A nuclear medicine dose of 2 millicurie converts to 74,000,000 becquerel (74 MBq). A much smaller source rated at 10 microcurie converts to 370,000 Bq — illustrating how quickly becquerel figures grow even for modest curie quantities. Running the numbers the other direction, 74,000,000 Bq converts back to exactly 2 mCi, confirming the conversion is exact in both directions.

Activity in becquerel and its SI multiples (kilobecquerel through terabecquerel) is how modern nuclear medicine labels radiotracer doses and how environmental monitoring reports contamination levels, while curie, millicurie, and microcurie remain common in US clinical practice, industrial radiography source labeling, and consumer products like the tiny americium-241 source inside an ionization smoke detector. Picocurie shows up specifically in radon test results, where residential air readings are reported in picocurie per liter. Environmental agencies reporting contamination levels after an incident typically use becquerel per unit area or volume specifically because the SI unit scales cleanly across the enormous range a monitoring survey can turn up, from near-background levels to a hotspot many orders of magnitude higher.

Activity tells you how many atoms are decaying per second, not how dangerous that source is — a highly active source emitting low-energy, easily shielded radiation can be far less hazardous than a less active source emitting high-energy radiation, so activity alone (in Bq or Ci) is never a complete safety picture on its own. The rutherford, defined as one million becquerel, is included for completeness but is essentially obsolete and rarely appears in current data.

Because this category spans from picocurie to terabecquerel — roughly twenty orders of magnitude end to end — it's unusually easy to be off by a factor of a thousand when converting by hand. Double-checking the prefix on both the source and target unit before trusting a manual calculation is worth the extra few seconds. It helps to keep the scale of the range in mind: picocurie-level readings describe faint environmental traces, while a diagnostic nuclear-medicine dose can run to the tens of megabecquerel or more — figures that are easy to confuse if a prefix gets dropped along the way.

Activity isn't a fixed property of a sample — it decreases over time as a radioactive source decays, following that isotope's own half-life, so a becquerel or curie figure attached to a source is only strictly valid as of the date it was measured or calibrated. This is why radiotracer doses prepared for same-day nuclear medicine procedures are ordered in megabecquerel or millicurie amounts calculated to be correct at the time of injection, not at the time the source was originally produced.

Questions

How many becquerel are in 10 microcurie?

10 µCi equals 370,000 Bq, since one curie is 3.7×10¹⁰ becquerel and a microcurie is a millionth of that.

Which units does this radiation activity converter cover?

13 units in total, all referenced to the becquerel: becquerel, kilobecquerel, megabecquerel, gigabecquerel, terabecquerel, curie, millicurie, microcurie, nanocurie, picocurie, rutherford, disintegration per second, and disintegration per minute.

Why is this category so prone to rounding mistakes?

The units span roughly twenty orders of magnitude, from picocurie up to terabecquerel, so a single misplaced prefix turns an answer into something a thousand times too big or too small. It's worth sanity-checking a converted figure's order of magnitude against the original before trusting it.

Should a nuclear medicine dose be written in curie or becquerel?

US clinical practice generally labels radiotracer doses in millicurie or microcurie, while SI-based and international records use megabecquerel or gigabecquerel for the same doses — both describe identical activities, just on different historical scales.

Does a higher activity reading always mean a more dangerous source?

Not necessarily — activity only counts decays per second, not the energy or type of radiation released. A highly active source emitting weak, easily shielded radiation can pose less risk than a less active source emitting high-energy radiation, so activity alone doesn't determine hazard.